top of page

Flexible EMI Shielding Wire for High-Flex Motion

Flexible shielding wire uses ultra-fine tinsel (metal foil on a fiber core) braided into an EMI shield for cables that move. In MAEDEN’s in-house reliability lab (R=1.0, 60 rpm, 180°, 500 g), FS001 (basic-grade tinsel) reached 131,217 cycles vs 130 for round copper (~1,000×), with higher shielding effectiveness (dB) from 30 MHz–6 GHz, and about 38% lighter finished cable in the matrix build—for robotics, medical, and wearables.

Why conventional braids fail in motion

Solid or conventional stranded copper braid concentrates stress at bend points, work-hardens, microcracks, then opens EMI leakage paths. In continuous motion—robot joints, probes, wearables—shield life is a mechanical problem, not only a coverage-% problem.
Typical consequences of shield fatigue: EMI leakage into nearby ICs or sensors, signal attenuation or drift, and intermittent faults that are hard to reproduce. Prefer a high-flex tinsel braid when bend / torsion cycles, not static conductivity, dominate the duty.

Tested in MAEDEN’s in-house reliability lab under stated conditions (bending: R=1.0, 60 rpm, 180°, 500 g; EMI in dB). Comparison is FS001 (basic shielding grade / tinsel wire conductor) vs a normal round copper conductor—not vs high-coverage braided copper shields or competitor products.
Full frequency table and strand-vs-finished matrix sit in the next two sections.

It is not decorative textile sleeving. Specifiers typically call for high optical braid coverage; 100% coverage is not achievable with braid alone because of crossover apertures. At ~1 GHz and above, ask for shielding effectiveness in dB, not coverage % alone. Related constructions: Braided Wire, Tinsel Wire, Wire structure.

Lab data (bending + EMI + FS001)

Flex cycles to failure: FS001 (tinsel) 131,217 | Round copper 130 | ~1,009× (~1,000×) under the same conditions
Conditions: MAEDEN in-house reliability lab R=1.0, 60 rpm, 180°, 500 g
EMI SE @ 1 GHz: FS001 30.33 dB | Round copper 27.97 dB | Δ +2.36 dB
EMI Δ (13 freqs, 30 MHz–6 GHz): +0.88 to +4.41 dB (FS001 higher at every listed frequency)
Finished cable weight (matrix): 5.412 vs 8.758 g/m (~38% lighter)
FS001 strand: OD 0.1 mm / DCR 14.8 Ω/m / break 0.286 kg; finest tinsel 0.05 mm

EMI comparison table (dB)

FS001 vs round copper conductor (basic shielding grade). Unit: dB. Same in-house lab conditions as above.

Frequency
Round copper (dB)
FS001 (dB)
Δ FS001 − round copper (dB)
30M
46.56
49.3
2.74
50M
33.82
37.78
3.96
70M
38.36
41.68
3.32
100M
47.38
50.65
3.27
300M
26.53
29.83
3.3
500M
37.68
39
1.32
800M
36.94
38.02
1.08
900M
28.69
29.57
0.88
1G
27.97
30.33
2.36
1.5G
32.21
34.84
2.63
2.4G
22.86
26.24
3.38
5G
36.2
38.87
2.67
6G
37.64
42.05
4.41

Shielding levels matrix: solid round copper vs FS001-family tinsel (0.1 mm)

Under the same bend conditions (R=1.0, 60 rpm, 180°, 500 g), matrix data for 0.1 mm conductors show FS001-family tinsel lasting 267 bend cycles vs 15 for solid round copper. In a finished braided-mesh cable build, tinsel reaches 18,781 vs 188 bends (~100×) and is about 38% lighter (5.412 vs 8.758 g/m). Strand-level trade-offs: higher DCR and lower break load. The 131,217 vs 130 EMI-sheet cycles are a separate sample set under the same bend recipe.

Metric
Solid round copper (0.1 mm)
FS001-family tinsel (0.1 mm)
Notes
OD
0.1 mm
0.1 mm
Same OD
DCR
2.349 Ω/m
14.8 Ω/m
Trade-off: tinsel higher R
Break load (strand)
0.458 kg
0.286 kg
Trade-off: tinsel lower
Bending (strand)
15
267
R=1.0, 60 rpm, 180°, 500 g, in-house
Twisting (strand)
55
156
Same lab
Weight (strand)
0.068 g/m
0.0317 g/m
~53% lighter
Break load (finished cable)
23.446 kg
21.326 kg
3-core FEP cable; braided mesh
Bending (finished cable)
188
18,781
~100×; same bend conditions
Twisting (finished cable)
3,092
29,173
Same lab
Weight (finished cable)
8.758 g/m
5.412 g/m
~38% lighter

When to use vs standard copper braid

Choose flexible tinsel shielding when cables see continuous bending or torsion and conventional conductor fatigue is the failure mode. This lab set compares basic-grade tinsel conductor vs plain round copper—not vs high-coverage braided shields.
Keep conventional high-coverage copper braid for static or low-flex harnesses where maximum low-frequency conductivity matters more than continuous-flex life.

Need the full test method, fixture details, or a coverage / AWG recommendation? Request the test report from engineering.

What is flexible shielding wire?

A shielding conductor that uses tinsel (metal foil on fiber) elements braided into a high-flex EMI shield for dynamic cables—not decorative textile sleeving.

How many flex cycles does MAEDEN publish?

131,217 cycles for FS001 vs 130 for round copper conductor, tested in MAEDEN’s in-house reliability lab (R=1.0, 60 rpm, 180°, 500 g). About 1,000× under those conditions.

What braid coverage do I need for EMI at 1 GHz?

Industry guidance typically calls for high optical braid coverage; braid cannot reach 100%. Prefer shielding effectiveness in dB. MAEDEN in-house lab, FS001 vs round copper at 1 GHz: 30.33 dB vs 27.97 dB (+2.36 dB). Full 13-frequency table on this page.

Is this the same as decorative cable braided sleeving?

No. This page is about electrically conductive EMI shielding braid, not cosmetic textile sleeving.

Can I get a sample?

Yes—FS001 engineering sample via /emailus (typically ships 3–5 business days after payment).

Where does this link in the braid family?

See also Braided Wire for general braid conductors and Wire structure for composite braid constructions.

Cost
Screenshot from 2025-10-02 at 5:00:13 PM.png
MAEDEN Flexible Shielding wire packge.png

Request Your FS001™ Engineering Sample

Application Scenario (Multiple choice)

Helps us understand your usage scale and recommend the best match.

Help us understand your use case so we can analyze the best engineering solution.

Sample will be shipped within 3–5 business days after payment.